MÔ TẢ Đồng Hồ Vạn Năng FLUKE 101 KIT

THÔNG SỐ KỸ THUẬT Đồng Hồ Vạn Năng FLUKE 101 KIT
Fluke 101 Basic Digital Multimeter
| Electrical specifications | ||
| V AC (40-500Hz) | Range | 600.0 mV 6.000 V 60.00 V 600.0 V |
| Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V |
|
| Accuracy | 3.0% ±3 digit 1.0% ±3 digit |
|
| V DC | Range | 6.000 V 60.00 V 600.0 V |
| Resolution | 0.001 V 0.01 V 0.1 V |
|
| Accuracy | 0.5% ±3 digit | |
| Resistance Ohms | Range | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
| Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
|
| Accuracy | 0.5% ±3 digit 0.5% ±2 digit 0.5% ±2 digit 0.5% ±2 digit 0.5% ±2 digit 1.5% ±3 digit |
|
| Capacitance | Range | 50.00 nF 500.0 nF 5.000 µF 50.00 µF 100.0 µF |
| Resolution | 0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF |
|
| Frequency (10 Hz – 100 kHz) |
Range | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
| Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
|
| Duty cycle | Range | 0.1% to 99.9% |
| Resolution | 0.1% | |
| General specifications | ||
| CAT rating | CAT III 600 V | |
| V AC range | 600.0 V | |
| V DC range | 600.0 V | |
| Ohms range | 40.00 MΩ | |
| Auto shutoff | Y | |
| Continuity | Y | |
| Capacitor | 100.0 µF | |
| Frequency | 100.0 kHz | |
| Hold | No | |
| Duty cycle | Yes | |
| Size | 130 x 65 x 27mm | |
| Weight | 160 g | |
| Battery | Two AAA | |
| Warranty | 1 year | |
| Environmental specifications | ||
| Operating temperature | 0 °C to +40 °C | |
| Storage temperature | -30 °C to +60 °C | |
| Operating humidity | Non condensing (<10 °C) <=90% RH (at 10 °C to 30 °C) <=75% RH (at 30 °C to 40 °C) (Without condensation) |
|
| Operating humidity, 40 MΩ | 80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C | |
| Operating altitude | 2,000 meters | |
| Storage altitude | 12,000 meters | |
| IP rating | IP 40 per IEC 60529 | |
| Vibration requirements | MIL-PRF-28800F, Class 2 | |
| Drop test requirements | -10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment Shipping container drop per Fluke SOP 39. |
|
| EMI, RFI, EMC | Must meet all applicable requirements in IEC/EN 61326-1 |
|
| Absorption/corrosion | Per Fluke SOP 39.1 | |
| Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC | |
Fluke i400E AC Current Clamp
| Electrical specifications | |
| AC current range | 1 A to 400 A |
| Output signal 1 | mV/A ac |
| Accuracy | 2.0% ±5 digits (45 Hz to 65 Hz) 2.5% ±5 digits (65 Hz to 400 Hz) |
| Typical bandwith | 5 Hz to 20 kHz |
| Working voltage | 600 V ac rms, in compliance with IEC 61010-1 and IEC 61010-2-030 |
| Load impedance | 1 A to 400 A |
| Maximum non-destructive current | 600 A |
| Jaw inner diameter | 30 mm |
| Maximum wire size | 600 MCM |
| Standard plugs | 19.04 mm dual banana plugs |
| Safety specifications | |
| Category rating | IEC 61010-1 and IEC 61010-2-030/IEC 61010-2-031 and IEC 61010-2-032: 600 V CAT III Pollution Degree 2 |
| Electromagnetic environment | IEC 61326-1: Portable |
| General specifications | |
| Output cable length | 1 m |
| Operating temperature | -10 °C to +50 °C |
| Storage temperature | -30 ºC to +60 ºC |
| Relative humidity | ≤90% at 10 °C to 530 °C ≤75% at 30 °C to 540 °C ≤45% at 40 °C to 50 °C |
| IP rating | IEC 60529: IP30 when jaw closed |
| Temperature coefficients | Add 0.1 x specified accuracy for each °C above 28°C or below 18 °C. |
| Operating altitude | 2,000 meters |
| Storage altitude | 12,000 meters |
| Vibration requirements | MIL-PRF-28800F, Class 2 |
| Drop test requirements | -10 °C, 1m, 6 sides, oak wood |
| Jaw impact test requirements | Follow EN/IEC 61010-2-032:2012 |
| EMI, RFI, EMC | IEC/EN 61326-1 |
| Dimensions (H x W x D) | 146 x 62 x 34 mm |
| Weight | 150 g |
ỨNG DỤNG Đồng Hồ Vạn Năng FLUKE 101 KIT